Ceco Performance and Conformance Standards

           PERFORMANCE TESTING
 

Physical Endurance 

Measures a door assembly's ability to resist deterioration resulting from expected usage.

The Test consists of two parts: 

  • Swing Test  -  (ANSI A250.4-01) Door  -  Door is open and closed a prescribed number of times. Refer to Fig. #1
  • Twist Test  -  (ANSI A250.4-01) Door 

  • Periodically throughout the Swing Test, a 300 lb. load is applied to one of the door's corners to gauge the door's ability to resist permanent deflection. 

Fig. #1
ANSI A-250.4 & 5 - Performance
DOOR
FACE
SHEET 
MINIMUM 
  THICKNESS 
Cycles 
                     the following table is in thousands of cycles
MSG 
(gage)
 IP ( " ) 
 SI (mm) 
  250
 500 
1,000
2,000
4,000
20
.032
0.8
*
*
     
18
.042
1.0
*
*
*
*

16 
.053 
1.3
*
*
*
*
*
14
067
1.6
*
*
*
   
 



Structural Performance 

Measures a door assembly's ability to resist static loads similar to those caused by high winds.

  • Test  -  ASTM E330-90, "Structural Performance by Uniform Static Air Pressure Difference"

  • Doors were mounted with Mortise lock and 4.5" x .134" butt hinges. Refer to Fig. #2 
Fig. #2 
        ASTM E330-90 Structural Performance
Static Loads - PSF
3'0" x 7'0" (Max. Size)           4"0" x 8'0" (Max. Size) 
DOOR
DESIGN
FACE
SHEET
GAGE
 Inswing Outswing Inswing Outswing
Regent
Door
20 
18 
16 
14 
110 
110 
110 
110
110
110
-
60
75
-
-
75
75
Imperial
Door
20 
18 
16 
14 
110 
110
110
110 
110
110
110
110 

75
-
-
75
-
Medallion
Door
18 
16 
14 
110
110
110 
110
110
110 
75
-
75
-
 



 Security 

Measures a door assembly's ability to resist, delay, and frustrate certain burglar attacks. "Attacks" as defined by the NILECJ standard.

Test  -  ASTM F476

HIGH SECURITY LEVEL
Ceco Door assemblies conform to Classification Grade 40. Grade 40 is the highest rating available under this ASTM test method and is suitable for use in commercial buildings in high crime areas with a high incidence of semi-skilled burglary attacks.
 



Conformance Standards
Conformance to National and Internationally Accepted Specifications and Standards. 
When properly specified, Ceco doors and frames will conform to the document 
requirements of the nationally recognized agencies listed below; the list is not all inclusive.

04-04M Section 08110: Veterans Administration Master Specification

ICC/ANSI A117.1-2003: Accessible and Usable Buildings and Facilities. 

ANSI A250.3-1999: Test procedure and acceptance criteria for factory applied painted steel surfaces for steel doors and frames.

ANSI A250.8-03: Recommended Specs Standard Steel Doors and Frames,SDI-100.

ANSI A250.10-2004: Test procedure and acceptance criteria for prime painted surfaces for steel doors and frames

ANSI A250.13: Testing and rating of severe windstorm resistant components for swinging door assemblies

ANSI/NAAMM HMMA861-00: Commercial Hollow Metal Doors and frames

ANSI/NAAMM HMMA863-04:  Guide Specification for Detention Security Hollow Metal Doors and Frames

ANSI/NAAMM HMMA865-03:  Guide Specifications for Swinging Sound Control Doors and Frames

ANSI/NAAMM HMMA866-01:  Guide Specifications for Stainless Streel Hollow Metal Doors and Frames

ANSI A115: Standard Specs. For Door and Frame Hardware Preparation. 

ANSI A156.7: Standard Template Hinge Dimension.

ANSI/NFPA 101: Life Safety Code

ANSI/NFPA 105: Installation of Smoke and Draft Control Assemblies.

ANSI/NFPA 80: Fire Doors and Windows. 

ANSI/NFPA 252: Standard Methods of Tests of  Door Assemblies. 

ANSI/NFPA 257: Fire test of Window Assemblies. 

BS 476 Parts 20 & 22-'87: Fire test on Bldg. Mtls. and Structures (British)

CAN4-S104-M80: National Standard of Canada standard method of fire tests of door assemblies

CEGS-08110: Steel Doors and Frames — Corps of Engineers Guide Specification

CFR Title 46
: US Coast Guard Requirement.

FEMA 320: Taking Shelter from the Storm: Building a Safe Room Inside Your House

FEMA 361: Design and Construction  Guidance for Community Shelters

HMMA810: Hollow Metal Doors, NAAMM. 

HMMA820: Hollow Metal Frames, NAAMM. 

HMMA860: Hollow Metal Doors and Frames, NAAMM. 

International Building Code  (IBC)

NASA-08110-04: N
ational Aeronautics and Space Administration

NBR 11742: Fire Test of Door Assemblies (Brazil) 

NCH 935 / 2.0: Fire Test of Door Assemblies (Chile) 

Florida Building Code, 2001 Edition.

SDI-113-01: Standard practice for determining the steady state thermal transmittance of steel doors and frames.

SDI-117-00: Manufacturing tolerances for standard steel doors and frames.

SDI-128-97: Guidelines for acoustical performance of standard steel doors and frames.

SS 332: Fire Test of Door Assemblies (Singapore)

UBC 7-2(1997): Fire test of door assemblies

UBC 7-4: Fire test of Window Assemblies under Positive Pressure.

UL305: Standard for Panic Hardware.

UL752:
Bullet Resistant Equipment.

UL9:
Fire test of Window Assemblies.

UL10B:
Fire test of Door Assemblies

UL10C:
Standard for Positive Pressure Fire Tests of Door Assemblies


UL1784:
Air Leakage Tests of Door Assemblies

UFGS-08110: Steel Doors and Frames United Facilities Guide Specification 


ISO 9001 CERTIFICATION
Updated April, 2004

                      Back to Products Page